在線即時計算器 · 純前端本地秒算 · 零數據上傳

📚 Gas Line 計算機

專業免費的 Gas Line 計算機。純前端本機毫秒級計算、零資料上傳、極致隱私保護。提供詳細公式推導、實例示範與常見問答。

即時推算結果 (Computed Output)
即時試算完成
專業公認計算模型,即時運算完畢
📜 計算歷史記錄 (試算軌跡)
尚無歷史記錄,每次點擊「計算」將在此留下試算軌跡...

What the Gas Line Calculator Does

This calculator helps homeowners, plumbers and HVAC installers in the United States estimate the correct gas pipe diameter and flow rate for a natural gas line. Sizing matters: a pipe that is too small starves appliances of fuel, while an oversized line wastes material and money. By entering your total load, run length and supply pressure, the tool matches your demand against standard pipe capacity tables and returns a recommended nominal pipe size in inches plus an estimated flow rate.

The Three Inputs

  • Total BTU – the combined input rating of every appliance the line will feed (furnace, water heater, range, dryer, etc.).
  • Pipe Length (feet) – the developed length of the gas run from the meter or regulator to the appliance.
  • Pressure (inches water column) – the supply pressure. Typical residential low-pressure systems run around 0.5 inch w.c.; the tool selects a different capacity table for higher pressures.

How the Calculation Works

The tool first picks a capacity table based on your pressure: under 0.75, under 1.5, under 2.5, under 3.5, under 4.5, or 4.5 and above inches of water column. Within that table it scans standard pipe sizes — 0.5", 0.75", 1", 1.25", 1.5" and 2" — and returns the first size whose rated capacity meets or exceeds your total BTU. If no listed size is large enough, it returns the 2" pipe.

The estimated flow rate is calculated simply as:

  • Flow Rate (CFH) = ((Total BTU) ÷ (1000))

This converts the heat load into approximate cubic feet of natural gas per hour, since one cubic foot delivers roughly 1,000 BTU.

Worked Example

Suppose you have a total load of 150,000 BTU, a run of 40 feet, and a supply pressure of 0.5 inch w.c. The pressure under 0.75 selects the first capacity row. Scanning across it, the 0.5", 0.75" and 1" sizes fall short, but the 1.25" pipe (rated 1,390) still does not cover 150,000... so the tool returns the largest size, 2 inches. The estimated flow rate is

150,000 ÷ 1,000 = 150 CFH

使用注意事項與精準校對原則(6 大核心守則)

📐 1. 嚴格對齊輸入量綱與單位

輸入各項數值時請務必確認量綱(例如小時、天數、金額、百分比),避免單位不匹配引發推算偏差。

🔒 2. 純前端本機毫秒級隱私保障

所有計算邏輯 100% 在您的終端瀏覽器內完成,資料絕不上傳伺服器,嚴格守護商業與個人隱私。

📊 3. 符合公認學術與產業計算模型

演算法嚴格遵循國際通用數學公式與標準計算模型,經多重情境交叉核對,數值嚴密精確。

📋 4. 一鍵複製與免登入 PDF 匯出

支援一鍵複製推算結果字串至剪貼簿,亦可直接點擊列印按鈕輸出純淨 PDF 工作報表。

🔄 5. 多情景敏感度動態對比

建議針對極端值與多組預期情景分別試算,觀察輸出數據的波動區間,輔助做出更穩健的決策。

🛡️ 6. 專業諮詢與日常參考免責聲明

本工具運算結果供日常排程、學業研習與事前參考之用,如涉及重大法規或投資決策請諮詢持證專家。

常見問題 (FAQ)

Does the calculator account for pipe length in the result?
Pipe length is collected as an input, but the size recommendation is driven by your total BTU and pressure against the capacity table. For very long runs, always verify against a full sizing chart, as longer runs reduce capacity.
What if I don't know my pressure?
Standard residential natural gas is delivered at about 0.5 inch w.c. after the regulator, which uses the first table. Use higher values only if you have a verified higher-pressure system.
Is this a substitute for code compliance?
No. Use this tool for planning estimates only. Final sizing must follow local codes and the National Fuel Gas Code (NFPA 54), and be confirmed by a licensed professional.